A note about
Static Electricity
EMI’s standard weigh scale control system employs special circuitry to minimize interference from static electricity. Among the several brands of weigh scale systems available, we have found this system to be superior in operation at typical plastic processing plants. Some molders add an ionizing unit to further reduce interference, particularly when molding nylons and styrenes. An additional benefit to using an ionizer is reducing dust and dirt attraction to parts.



Automated Container Filling Systems
Cycle Count l Weigh Scale l Weigh Hopper l In Line l Side by Side
Over Under l Turntable l Bagfilling l Trunkline l Tote Dispenser l Portable l Robotic

Weigh Scale Automation Systems
A weigh scale system is an excellent choice when a high degree of accuracy is required. Many molders choose a weigh scale system when small parts need to be packed into shipping or storage containers, because it minimizes the chances of too few parts being packed because of machine failure, bad shots, etc.
Weigh Scale: Systems l Applications
Automated weigh scale systems such as this, are sized to meet your container and floor space requirements. Systems include selected EMI under press and beside press conveyors (one with a weigh scale and photo-eye) and a customized control system.

Sequence of Operation

  1. The empty box is conveyed onto the scale and positioned by photo-eye.
  2. Empty box tare weight is deducted by the control system.
  3. Under press conveyor runs until the preset weight has been conveyed into the box.
  4. At preset weight signal, the controls:
    • momentarily stop the under press conveyor. . .
    • start the scale conveyor to move the full box while positioning an empty one . . .
    • repeats the tare deduction and other sequences.

Weigh Scale Conrols:
The NEMA 1 enclosure includes a weigh scale push button control and display for the platform. A cleat-sensing limit switch, mounted on the empty box holding conveyor, ensures positive container movement. A photo-eye assures correct positioning. Also included: on/off switch, manual reset button, programmable control and interfacing relay.

A recommended option is the No Empty Box alarm, with Alarm Condition indicator.


Simple Installation:
Once the under press and beside press conveyors are positioned, the system can be plugged in. Conveyors, weigh scale and photo-eye are pre-wired into the control system. The under press conveyor plugs into the control system. The operator then simply enters the desired weight or piece count into the scale control.
© 2007 EMI Plastics Equipment. All rights reserved. Contact us at 800-543-6169 or Sales@EMIplastics.com